As any engineering project requires significant amounts of time dedicated to manufacturing physical products, a modern engineering laboratory should include a range of manufacturing tools including lathes, saws, broaching machines, drill presses, shapers, milling machines, and CNC (computer numerical control) machine

Facilities

  • AC /DC Distribution panel
  • Rectifier: 100A , 200 V - 250V DC – Servo controlled Rectifier unit
  • DC Shunt Motor, 220V, 19A/3.7 KW coupled with DC Shunt  generator, 220V, 16A / 3.5KW, Thyristor controlled  DC  drive - 0-250V  for 5 HP DC  motor. (Kirloskar)
  • DC Shunt Motor, 220V, 19A/3.5 KW coupled with DC Shunt  generator, 220V, 16A / 3.5KW (Kirloskar)
  • DC MCB, indicator, Fuses, DC starter, Toroidal type field rheostats, Digital voltmeters, Digital Ammeters and Digital Tachometer.
  • DC Shunt Motor, 220V / 3.5 KW /1500  RPM with the mechanical loading arrangement consists  of  aluminum  drum  and scales with  powder  coated MS channel  and  anti-vibration pads.(Kirloskar Electric company make)
  • DC Series Motor, 220V, 3.5 KW /1500 RPM with the mechanical loading arrangement consists of Aluminum pulley, scales with powder coated MS channel and anti-vibration pads. ( Kirloskar electric make )
  • DC Shunt Motor, 220V/5.2 KW/1500 rpm coupled with 3 phase / 5 KVA/415V/1500  rpm Alternator (Kirloskar)
  • DC Shunt Motor- 220V/ 5.2 KW coupled with 3 phase/ 415V/ 1500 rpm / 5KVA  Alternator, Synchronizing  panel ( Kirloskar Electric make)
  • 3-Phase Squirrel Cage Induction Motor 5hp/415V / 1440 rpm with brake drum Loading Arrangement, MCB, indicator, Fuses, DOL starter, Digital voltmeter, Digital Ammeter, Digital wattmeter and Digital Tachometer.  ( SIEMENS  and ABB  make )
  • 1-Phase Transformers - LV: 115V, HV: 230V, KVA Rating: 2 KVA, Tappings at 0V, 50%, 86.6% & 100% on LV and HV side, 3-phase Auto transformer -20 Amps
  • 1-Phase Transformers LV: 115V, HV: 230V, KVA Rating: 2 KVA and 1 KVA, 1-phase Auto transformer -20 Amps
  • Universal Motor: 1 HP / 220V AC / DC with Mechanical Loading.

Experiments

 

  • No load and Load tests on DC Shunt Generator
  • Hopkinson’s test on DC Shunt Machines
  • No load, Load tests & Speed control on DC Shunt Motor
  • Load test on DC Series Motor
  • No load & short circuit tests on 3-phase Alternator
  • Synchronization of 3-phase Alternator
  • No load, load tests & blocked rotor test on 3-phase Squirrel Cage Induction Motor
  • Scott connection of 1-phase Transformers
  • Parallel operation of 1-phase Transformers
  • Open circuit(OC) & short circuit(SC) tests of 1-phase Transformer

Experiments

 

  • No load and Load tests on DC Shunt Generator
  • Hopkinson’s test on DC Shunt Machines
  • No load, Load tests & Speed control on DC Shunt Motor
  • Load test on DC Series Motor
  • No load & short circuit tests on 3-phase Alternator
  • Synchronization of 3-phase Alternator
  • No load, load tests & blocked rotor test on 3-phase Squirrel Cage Induction Motor
  • Scott connection of 1-phase Transformers
  • Parallel operation of 1-phase Transformers
  • Open circuit(OC) & short circuit(SC) tests of 1-phase Transformer

OBJECTIVE

  • To provide knowledge on analysis and design of control system along with basics of instrumentation.

LIST OF EQUIPMENTS

  • DC Servo motor Kit
  • AC Servo motor Kit
  • Rigged up module type 0 & type 1 system using analog components Kit
  • Stepper motor Kit
  • Complete closed loop DC position control Kit
  • Transfer function of DC generator & DC motor Kit
  • Complete closed loop AC position control Kit
  • AC Synchro Transmitter & Receiver Kit
  • Thermometer – RTD Kit
  • Thermistor (Silicon type) RTD nickel type Kit
  • Optical Sensor Kit
  • Strain Gauge Kit with Handy Lever beam Kit with 100gm weights
  • Flow measurement Trainer Kit
  • MATLAB – R2009b
  • Intel dual core/ intel MB/250GB/DVD writter/LG 15.6”/optical mouse/HCL keyboard/PST cabinet
  • LVDT kit
  • Maxwell’s bridge kit
  • Schering bridge kit
  • Wheat stone bridge kit
  • Kelvin double bridge kit
  • Calibration of single phase energy meter
  • Operational amplifier kit
  • Bourdon pressure transducer kit with foot pump Kit
  • Calibration of current transformer Kit
  • Measurement of iron loss kit with ring specimen
  • DC trainer kit
  • Three phase auto transformer
  • Three phase resistive load star connected
  • Three phase inductive load
  • Three phase capacitive load

The microprocessor is a multipurpose, clock driven, register based, digital integrated circuit that accepts binary data as input, processes it according to instructions stored in its memory, and provides results as output. •Microprocessors contain both combinational logic and sequential digital logic.
•Microprocessors operate on numbers and symbols represented in the binary number system.
• Demonstration and study of FASM software commands
• Write a program using 8086 & verify for arithmetic operations
• Average of n numbers
• Fibonacci series program
• Arrange the numbers in ascending order
• Matrix addition program
• Addressing modes using arithmetic operations
• Write a program to reverse the given string and store at the same location.
• Reversing the character order in the process by using loop instruction with indirect addressing
• Write an interrupt program using keyboard interrupt
• Stepper motor using kbint with 8086 & 8255 ppi
• Control traffic lights using interfacing
• Seven segment display using interfacing L